Victron Argofet 100-2 2 batteries 100A ARG100201020

https://batsol123-bat-sol-odoo-13052024-main-13132598.odoo.com/web/image/product.template/263343/image_1920?unique=e2006a4
Argofet 100-2 2 batteries 100A Similarly to diode battery isolators, FET isolators allow simultaneous charging of two or more batteries from one alternator (or a single output battery charger), without connecting the batteries together. Discharging the accessory battery for example will not result in also discharging the starter battery. When using ARGO FET Battery Isolators, there is no need to also increase the output voltage of the alternator. Care should taken however to keep cable lengths short and of sufficient cross section. Example: When a current of 100 A flows through a cable of 50 mm2 cross section (AWG 0) and 10 m length (30 ft), the voltage drop over the cable will be 0,26 Volt. Similarly a current of 50 A through a cable of 10 mm2 cross section (AWG 7) and 5 m length (15 ft) will result in a voltage drop of 0,35 Volt! Alternator energize input Some alternators need DC voltage on the B+ output to start charging. Obviously, DC will be present when the alternator is directly connected to a battery. Inserting a Diode or FET splitter will however prevent any return voltage/current from the batteries to the B+, and the alternator will not start. The new Argofet isolators have a special current limited energize input that will power the B+ when the engine run/stop switch is closed.   Important Notice: Please note that the images of the product shown above are for illustrative purposes only. While we strive to provide accurate representations, there might be slight differences between the product image and the actual product you receive. These variations could be due to lighting, individual screen settings, product enhancements, or minor design updates from the manufacturer. We assure you that any discrepancies are minimal and will not affect the overall quality and functionality of the product. If you have any questions or concerns, please feel free to contact our customer support team for further assistance at support@batsol.co.uk or phone us at 01752 656270. At Batteries and Solar, your satisfaction is our top priority, and we are committed to providing the best shopping experience for you. Thank you for choosing Batteries and Solar for your purchase. Key Features   Simultaneous Charging: Allows charging of two batteries from a single alternator or battery charger, without interconnecting the batteries. Prevents Discharge: Prevents the discharging of the accessory battery from discharging the starter battery. No Voltage Increase Required: Unlike diode isolators, Argofet isolators don't need an increase in alternator output voltage. Cable Considerations: Advises maintaining short cable lengths and sufficient cross-section to prevent voltage drops. Special Energize Input: Features a current-limited energize input for alternator powering. Voltage Drop Examples: Illustrates potential voltage drops based on cable size and current.   Specifications Maximum Charge Current (A) 100 Maximum Alternator Current (A) 100 Number Of Batteries 2 Connection M8 Studs Weight (kg) 1.4 Dimensions (mm) H65 x W120 x D200 Attachments Data Sheet

£ 74.46 74.46000000000001 GBP £ 74.46 VAT Excluded £ 89.35

£ 67.01 VAT Excluded £ 89.35

Not Available For Sale

  • ​Amps Range

This combination does not exist.

​Amps Range: 90+A

Internal Reference: 105618