Victron Isolation Tr. 7000W 230V ITR000702001

https://trade.batteriesandsolar.co.uk/web/image/product.template/261042/image_1920?unique=c961dc5
Victron Energy - Isolation Tr. 7000W 230V - ITR000702001Safety and prevention of galvanic corrosionThe Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms. Safety is taken for granted in case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire on board results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, conductivity of the fluid, temperature, nature of the materials, etc. It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install anIsolation Transformer to connect to the shore-side supply. The Isolation Transformer eliminates any electrical continuity between shore power and the boat. The shorepower is fed to the primary side of the transformer and the ship is connected to the secondary.The Isolation Transformer completely isolates the boat from the shore ground. By connecting all metal parts tothe neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a shortcircuit. Soft start is a standard feature of a Victron Energy isolation transformer. It will prevent the shore power fusefrom blowing due to the inrush current of the transformer, which would otherwise occur. It is also recommended, for optimal safety, to connect the secondary neutral of the transformer to groundwhen the boat is out of the water.3600 Watt Auto 115/230 VThis model will automatically switch to 115 V or 230 V supply, depending on input voltage.Supply 88 V 130 V: switches to 115 V supplySupply 185 250 V: switches to 230 V supply range.Note: The AC input voltage is raised by 1:1.05 ratio at the AC output.

£ 606.10 606.1 GBP £ 606.10 VAT Excluded £ 727.33

£ 545.49 VAT Excluded £ 727.33

Not Available For Sale

This combination does not exist.


Internal Reference: 101239